Notice: Missing <code>texvccheck</code> executable. Please see math/README to configure. in /var/www/html/extensions/Math/MathInputCheckTexvc.php on line 65
Hardened Fluiduct - ATLauncher Wiki
24,537 ARTICLES
ON THIS WIKI

Hardened Fluiduct

(Redirected from Hardened Fluiduct (Opaque))

Hardened Fluiduct
Hardened Fluiduct

Name Hardened Fluiduct
Source Mod Thermal Dynamics
ID Name
ThermalDynamics:ThermalDynamics_16:2
Type Block
Stackable Yes (64)
Blast Resistance 30.0
Hardness 1.0
Solid Yes
Transparent Yes
Affected by Gravity No
Emits Light with Lava inside
Flammable No
Required Tool Crescent Hammer

The Hardened Fluiduct is a block added by the Thermal Dynamics mod. Used to transport liquids. Compatible with most mods' machines and Tanks. Some machines such as the Aqueous Accumulator or Pump and some tanks such as a Portable Tank [1] will output to a connected Fluiduct automatically. The Fluiduct has an Opaque version that removes the ability to see the liquid inside, it is cheaper to make and may reduce lag. Opaque Fluiduct will still connect to regular Fluiducts. The transfer rate vary with the liquid tranported. This Fluiduct can transport extreme temperature liquids. The Fluiduct can carry only one type of liquid at a time and will not accept a different type unless completely empty. Each fluiduct can contain 3000mb (3 buckets) worth of liquid.

Recipe [2][edit]

GUI Crafting Table.png
Invar Ingot (Thermal Foundation)
Hardened Glass
Invar Ingot (Thermal Foundation)





Hardened Fluiduct
GridNumbersCSS.pngGridNumbersCSS.pngGridNumbersCSS.png
GUI Crafting Table.png
Shapeless
Hardened Fluiduct (Opaque)
Hardened Fluiduct (Opaque)
Fused Quartz
Hardened Fluiduct (Opaque)
Hardened Fluiduct (Opaque)


Hardened Fluiduct (Opaque)
Hardened Fluiduct (Opaque)


Hardened Fluiduct
GridNumbersCSS.pngGridNumbersCSS.pngGridNumbersCSS.png

Opaque[edit]

GUI Crafting Table.png
Invar Ingot (Thermal Foundation)
Lead Ingot
Invar Ingot (Thermal Foundation)





Hardened Fluiduct (Opaque)
GridNumbersCSS.pngGridNumbersCSS.pngGridNumbersCSS.png
GUI Crafting Table.png
Shapeless
Hardened Fluiduct
Hardened Fluiduct
Lead Ingot
Hardened Fluiduct
Hardened Fluiduct


Hardened Fluiduct
Hardened Fluiduct


Hardened Fluiduct (Opaque)
GridNumbersCSS.pngGridNumbersCSS.pngGridNumbersCSS.png

Feed The Beast Infinity Evolved Expert Mode[edit]

GUI Crafting Table.png
Hardened Lumium Glass


Invar Blend
Invar Blend
Hardened Glass
Invar Blend
Invar Blend


Hardened Lumium Glass


Hardened Fluiduct
GridNumbersCSS.pngGridNumbersCSS.pngGridNumbersCSS.png

Mechanics[edit]

Wrench[edit]

'Right click' on the connection with a Crescent Hammer or any Wrench to disconnect, inversely, 'Right click' on the side to be connected. 'Shift+Right-clicking' will remove the duct [3].

Configuration[edit]

The type of fluid extracted may be filtered and Redstone control activation setting changed using a Servo [4] or a Retriever to extract from a remote source. 'Right-clicking' the Fluiduct connection with the Servo will install it, 'Right-clicking' again will open the GUI, where the Redstone signal setting may be changed to Disabled, Low or High. A ghost image of a fluid can be added to the filter inventory (using a bucket) and set to White or Black list.

Transfer Rate[edit]

The rate [5] at which Fluiducts transfer their contents depends on the fluid transported and is calculated with the formula:

Where Rate of Flow is a value restricted to be between 80 and 600 mB per tick. The table below list some common fluids' transfer rates:

Fluid Viscosity Transfer Rate
mB/ tick
Water 1,000 120
Resonant Ender 3,000 80
Lava 6000 80
Steam 200 600
Destabilised Redstone 1,500 80
Energised Glowstone 100 600

Usage[edit]

Hardened Fluiduct can be used to create the following items:

See Also[edit]

The following items may also be of interest:

Note[edit]

  1. A Servo or Retriever is needed to extract from the side of a Portable Tank.
  2. Hardened Glass Hardened Glass can be substituted with the following items: Fused Quartz Fused Quartz, Hardened Lumium Glass Hardened Lumium Glass.
  3. When Removing the Fluiduct the liquid inside will be lost.
  4. A Filter may also be used on the receiving end [of a Servo] if the Duct system is used for multiple liquids and/ or outputs.
  5. As with all Thermal Dynamics ducts, the transfer rate is per connection.